1. Fluke VR1710 USB Drivers v10.1.8.2466 (.zip) These drivers are normally included on the software CD included with the VR-1710. Unzip the drivers to a suitable location and follow the instructions detailed in the user manual ( the user manual is available for download in the product pages ).
  2. Mtp Usb Device Driver free download - USB Mass Storage Device, USB Audio ASIO Driver, USB Video Device, and many more programs.
-->

Owner's Manual for Windows v3.4 USA-19HS USB Serial Adapter (English) Owner's Manual for USA-19HS Windows v3.7S (English) Owner's Manual for Mac OS 8.6 - 9.X USA-19HS USB Serial Adapter (English) Owner's Manual for Mac OS X USA-19HS USB Serial Adapter (English) Product Datasheet. Download driver Fluke 753/754 USB Driver version 1.1.0.0 for Windows XP, Windows Vista, Windows 7, Windows 8, Windows 8.1, Windows 10 32-bit (x86), 64-bit (x64). Screenshot of files File Name.

This topic is intended for OEMs who want to build a Windows 10 system with USB Type-C connector and want to leverage OS features that allow for faster charging, power delivery, dual role, alternate modes, and error notifications through Billboard devices.

A traditional USB connection uses a cable with a USB A and USB B connector on each end. The USB A connector always plugs in to the host side and the USB B connector connects the function side, which is a device (phone) or peripheral (mouse, keyboard). By using those connectors, you can only connect a host to a function; never a host to another host or a function to another function. The host is the power source provider and the function consumes power from the host.

The traditional configuration limits some scenarios. For example, if a mobile device wants to connect to a peripheral, the device must act as the host and deliver power to the connected device.

The USB Type-C connector, introduced by the USB-IF, defined in the USB 3.1 specification, addresses those limitations. Windows 10 introduces native support for those features.

Download Fluke USB Devices Driver

Feature summary

  • Allows for faster charging up to 100W with Power Delivery over USB Type-C.
  • Single connector for both USB Hosts and USB Devices.
  • Can switch USB roles to support a USB host or device.
  • Can switch power roles between sourcing and sinking power.
  • Supports other protocols like DisplayPort and Thunderbolt over USB Type-C.
  • Introduces USB Billboard device class to provide error notifications for Alternate Modes.

Official specifications

Hardware design

USB Type-C connector is reversible and symmetric.

The main component are: the USB Type-C connector and its port or PD controller that manages the CC pin logic for the connector. Such systems typically have a dual-role controller that can swap the USB role from host to function. It has Display-Out module that allows video signal to be transmitted over USB. Optionally it can support BC1.2 charger detection.

Consider recommendations for the design and development of USB components, including minimum hardware requirements, Windows Hardware Compatibility Program requirements, and other recommendations that build on those requirements.Hardware component guidelines USB

Vr1710 usb driver

Choose a driver model

Use this flow chart to determine a solution for your USB Type-C system.

If your system...Recommended solution...
Does not implement PD state machinesWrite a client driver to the UcmTcpciCx class extension.
Write a USB Type-C port controller driver
Implements PD state machines in hardware or firmware and support USB Type-C Connector System Software Interface (UCSI) over ACPILoad the Microsoft provided in-box drivers, UcmUcsiCx.sys and UcmUcsiAcpiClient.sys.
See UCSI driver.
Implements PD state machines in hardware or firmware, but either does not support UCSI, or support UCSI but requires a transport other than ACPIWrite a client driver for the UcmCx class extension.
Write a USB Type-C connector driver
Write a USB Type-C Policy Manager client driver
Implements UCSI but requires a transport other than ACPIWrite a client driver to the UcmUcsiCx class extension.
Use this sample template and modify it based on a transport that your hardware uses.
Write a UCSI client driver

Bring up drivers

  • USB Function driver bring-up is only required if you support USB Function mode. If you previously implemented a USB Function driver for a USB micro-B connector, describe the appropriate connectors as USB Type-C in the ACPI tables for the USB Function driver to continue working.

    For more information, see instructions about writing a USB Function driver.

  • USB Role-Switch driver bring-up is only required for devices that have a Dual Role controller that assumes both Host and Function roles. To bring-up the USB Role-Switch driver, you need to modify the ACPI tables to enable the Microsoft in-box USB role-switch driver.

    For more information, see the guidance for bringing up the USB Role Switch Driver.

  • A USB Connector Manager Driver is required for Windows to manage the USB Type-C ports on a system. The bring-up tasks for a USB Connector Manager driver depend on the driver that you choose for the USB Type-C ports: The Microsoft in-box UCSI (UcmUcsiCx.sys and UcmUcsiAcpiClient.sys) driver, a UcmCx client driver, or a UcmTcpciCx client driver. For more information, see the links in the preceding section that describe how to choose the right solution for your USB Type-C system.

Test

Perform various functional and stress tests on systems and devices that expose a USB Type-C connector.

Test USB Type-C systems with USB Type-C ConnEx - Run USB tests included in the Windows Hardware Lab Kit (HLK) for Windows 10.

Run USB function HLK tests with a C-to-A cable (search for Windows USB Device in the HLK

Certification/ComplianceAttend Power Delivery and USB Type-C compliance workshops hosted by the standards bodies.

See also

-->

This topic describes the WDF-provided continuous reader object. The procedures in this topic provide step-by-step instructions about how to configure the object and use it to read data from a USB pipe.

Windows Driver Framework (WDF) provides a specialized object called the continuous reader. This object enables a USB client driver to read data from bulk and interrupt endpoints continuously, as long as there is data available. In order to use the reader, the client driver must have a handle to a USB target pipe object that is associated with the endpoint from which the driver reads data. The endpoint must be in the active configuration. You can make a configuration active in one of two ways: by selecting a USB configuration or by changing the alternate setting in the current configuration. For more information about those operations, see How to Select a Configuration for a USB Device and How to select an alternate setting in a USB interface.

After creating the continuous reader, the client driver can start and stop the reader as and when necessary. The continuous reader that ensures that a read request is always available on the target pipe object and the client driver is always ready to receive data from the endpoint.

The continuous reader is not automatically power managed by the framework. This means that the client driver must stop the reader when the device enters a lower power state and restart the reader when the device enters working state.

What you need to know

Technologies

Prerequisites

Before the client driver can use the continuous reader, make sure that these requirements are met:

  • Your USB device must have an IN endpoint. Check the device configuration in USBView. Usbview.exe is an application that allows you to browse all USB controllers and the USB devices connected to them. Typically, USBView is installed in the Debuggers folder in the Windows Driver Kit (WDK).

  • The client driver must have created the framework USB target device object.

    If you are using the USB templates that are provided with Microsoft Visual Studio Professional 2012, the template code performs those tasks. The template code obtains the handle to the target device object and stores in the device context.

    KMDF client driver:

    A KMDF client driver must obtain a WDFUSBDEVICE handle by calling the WdfUsbTargetDeviceCreateWithParameters method. For more information, see 'Device source code' in Understanding the USB client driver code structure (KMDF).

    UMDF client driver:

    A UMDF client driver must obtain an IWDFUsbTargetDevice pointer by querying the framework target device object. For more information, see 'IPnpCallbackHardware implementation and USB-specific tasks' in Understanding the USB client driver code structure (UMDF).

  • The device must have an active configuration.

    If you are using USB templates, the code selects the first configuration and the default alternate setting in each interface. For information about how to change the alternate setting, see How to select an alternate setting in a USB interface.

    KMDF client driver:

    A KMDF client driver must call the WdfUsbTargetDeviceSelectConfig method.

    UMDF client driver:

    For a UMDF client driver, the framework selects the first configuration and the default alternate setting for each interface in that configuration.

  • The client driver must have a handle to the framework target pipe object for the IN endpoint. For more information, see How to enumerate USB pipes.

Fluke Usb Drivers For Windows

Instructions

Using the continuous reader - KMDF client driver

  1. Configure the continuous reader.

    1. Initialize a WDF_USB_CONTINUOUS_READER_CONFIG structure by calling the WDF_USB_CONTINUOUS_READER_CONFIG_INIT macro.
    2. Specify its configuration options in the WDF_USB_CONTINUOUS_READER_CONFIG structure.
    3. Call the WdfUsbTargetPipeConfigContinuousReader method.

    The following example code configures the continuous reader for the specified target pipe object.

Typically the client driver configures the continuous reader in the EvtDevicePrepareHardware callback function after enumerating the target pipe objects in the active setting.

Devices

In the preceding example, the client driver specifies its configuration options in two ways. First by calling WDF_USB_CONTINUOUS_READER_CONFIG_INIT and then by setting WDF_USB_CONTINUOUS_READER_CONFIG members. Notice the parameters for WDF_USB_CONTINUOUS_READER_CONFIG_INIT. These values are mandatory. In this example, the client driver specifies:

Download Fluke Usb Devices Driver Windows 7

  • A pointer to a completion routine that the driver implements. The framework calls this routine when it completes a read request. In the completion routine, the driver can access the memory location that contains the data that was read. The implementation of the completion routine is discussed in step 2.
  • A pointer to the driver-defined context.
  • The number of bytes that can be read from the device in a single transfer. The client driver can obtain that information in a WDF_USB_PIPE_INFORMATION structure by calling WdfUsbInterfaceGetConfiguredPipeor WdfUsbTargetPipeGetInformation method. For more information, see How to enumerate USB pipes.

WDF_USB_CONTINUOUS_READER_CONFIG_INIT configures the continuous reader to use the default value for NumPendingReads. That value determines the number of read requests that the framework adds to the pending queue. The default value has been determined to provide reasonably good performance for many devices on many processor configurations.

In addition to the configuration parameters specified in WDF_USB_CONTINUOUS_READER_CONFIG_INIT, the example also sets a failure routine in WDF_USB_CONTINUOUS_READER_CONFIG. This failure routine is optional.

In addition to the failure routine, there are other members in WDF_USB_CONTINUOUS_READER_CONFIG that the client driver can use to specify the layout of the transfer buffer. For example, consider a network driver that uses the continuous reader to receive network packets. Each packet contains header, payload, and footer data. To describe the packet, the driver must first specify the size of the packet in its call to WDF_USB_CONTINUOUS_READER_CONFIG_INIT. Then, the driver must specify the length of the header and footer by setting HeaderLength and TrailerLength members of WDF_USB_CONTINUOUS_READER_CONFIG. The framework uses those values to calculate the byte offsets on either side of the payload. When payload data is read from the endpoint, the framework stores that data in the part of the buffer between the offsets.

  1. Implement the completion routine.

    The framework invokes the client-driver implemented completion routine each time a request is completed. The framework passes the number of bytes read and a WDFMEMORY object whose buffer contains the data that is read from the pipe.

    The following example code shows the completion routine implementation.

Fluke Usb Drivers

The framework invokes the client-driver implemented completion routine each time a request is completed. The framework allocates a memory object for each read operation. In the completion routine, the framework passes the number of bytes read and a WDFMEMORY handle to the memory object. The memory object buffer contains the data that is read from the pipe. The client driver must not free the memory object. The framework releases the object after each completion routine returns. If the client driver wants to store the received data, the driver must copy the contents of the buffer in the completion routine.

  1. Implement the failure routine.

    The framework invokes the client-driver implemented failure routine to inform the driver that the continuous reader has reported an error while processing a read request. The framework passes the pointer to the target pipe object on which the request failed and error code values. Based on those error code values the driver can implement its error recovery mechanism. The driver must also return an appropriate value that indicates to the framework whether the framework should restart the continuous reader.

    The following example code shows a failure routine implementation.

In the preceding example, the driver returns TRUE. This value indicates to the framework that it must reset the pipe and then restart the continuous reader.

Alternatively, the client driver can return FALSE and provide an error recovery mechanism if a stall condition occurs on the pipe. For example, the driver can check the USBD status and issue a reset-pipe request to clear the stall condition.

For information about error recovery in pipes, see How to recover from USB pipe errors.

  1. Instruct the framework to start the continuous reader when the device enters working state; stop the reader when the device leaves working state. Call these methods and specify the target pipe object as the I/O target object.

    The continuous reader is not automatically power managed by the framework. Therefore, the client driver must explicitly start or stop the target pipe object when the power state of the device changes. The driver calls WdfIoTargetStart in the driver's EvtDeviceD0Entry implementation. This call ensures that the queue delivers requests only when the device is in working state. Conversely, the driver calls WdfIoTargetStop in the drivers EvtDeviceD0Exit implementation so that the queue stops delivering requests when the device enters a lower power state.

Download Fluke Usb Devices Driver Updater

The following example code configures the continuous reader for the specified target pipe object.

The preceding example shows the implementation for EvtDeviceD0Entry and EvtDeviceD0Exit callback routines. The Action parameter of WdfIoTargetStop allows the client driver to decide the action for the pending requests in the queue when the device leaves working state. In the example, the driver specifies WdfIoTargetCancelSentIo. That option instructs the framework to cancel all pending requests in the queue. Alternatively, the driver can instruct the framework to wait for pending requests to get completed before stopping the I/O target or keep the pending requests and resume when the I/O target restarts.

Using the continuous reader - UMDF client driver

Before you start using the continuous reader, you must configure the reader in your implementation of IPnpCallbackHardware::OnPrepareHardware method. After you get a pointer to IWDFUsbTargetPipe interface of the target pipe object associated with the IN endpoint, perform these steps:

Configure the continuous reader

  1. Call QueryInterface on the target pipe object (IWDFUsbTargetPipe) and query for the IWDFUsbTargetPipe2 interface.

  2. Call QueryInterface on the device callback object and query for the IUsbTargetPipeContinuousReaderCallbackReadComplete interface. In order to use the continuous reader, you must implement IUsbTargetPipeContinuousReaderCallbackReadComplete. The implementation is described later in this topic.

  3. Call QueryInterface on the device callback object and query for the IUsbTargetPipeContinuousReaderCallbackReadersFailed interface if you have implemented a failure callback. The implementation is described later in this topic.

  4. Call the IWDFUsbTargetPipe2::ConfigureContinuousReader method and specify the configuration parameters, such as header, trailer, number of pending requests, and references to the completion and failure callback methods.

    The method configures the continuous reader for the target pipe object. The continuous reader creates queues that manage a set of read requests as they are sent and received from the target pipe object.

The following example code configures the continuous reader for the specified target pipe object. The example assumes that the target pipe object specified by the caller is associated with an IN endpoint. The continuous reader is configured to read USBD_DEFAULT_MAXIMUM_TRANSFER_SIZE bytes; to use the default number of pending requests using by the framework; to invoke the client driver-supplied completion and failure callback methods. Buffer received will not contain any header or trailer data.

Next, specify the state of the target pipe object, when the device enters and exits a working state (D0).

If a client driver uses a power-managed queue to send requests to a pipe, the queue delivers requests only when the device is in the D0 state. If the power state of the device changes from D0 to a lower power state (on D0 exit), the target pipe object completes the pending requests and the queue stops submitting requests to the target pipe object. Therefore, the client driver is not required to start and stop the target pipe object.

The continuous reader does not use power-managed queues to submit requests. Therefore, you must explicitly start or stop the target pipe object when the power state of the device changes. For changing the state of the target pipe object, you can use the IWDFIoTargetStateManagement interface implemented by the framework. After you get a pointer to IWDFUsbTargetPipe interface of the target pipe object associated with the IN endpoint, perform the following steps:

Implement state management

  1. In your implementation of IPnpCallbackHardware::OnPrepareHardware, call[QueryInterface on the target pipe object (IWDFUsbTargetPipe) and query for the IWDFIoTargetStateManagement interface. Store the reference in a member variable of your device callback class.
  2. Implement the IPnpCallback interface on the device callback object.
  3. In the implementation of the IPnpCallback::OnD0Entry method, call IWDFIoTargetStateManagement::Start to start the continuous reader.
  4. In the implementation of the IPnpCallback::OnD0Exit method, call IWDFIoTargetStateManagement::Stop to stop the continuous reader.

After the device enters a working state (D0), the framework calls the client-driver supplied D0-entry callback method that starts the target pipe object. When the device leaves the D0 state, the framework calls the D0-exit callback method. The target pipe object completes the number of pending read requests, configured by the client driver, and stops accepting new requests.The following example code implements the IPnpCallback interface on the device callback object.

The following example code shows how to get a pointer to the IWDFIoTargetStateManagement interface of the target pipe object in the IPnpCallback::OnPrepareHardware method

The following example code shows how to get a pointer to the IWDFIoTargetStateManagement interface of the target pipe object in the IPnpCallbackHardware::OnPrepareHardware method.

After the continuous reader completes a read request, the client driver must provide a way to get notified when the request completes a read request successfully. The client driver must add this code to the device callback object.

Provide a completion callback by implementing IUsbTargetPipeContinuousReaderCallbackReadComplete

  1. Implement the IUsbTargetPipeContinuousReaderCallbackReadComplete interface on the device callback object.
  2. Make sure the QueryInterface implementation of the device callback object increments the reference count of the callback object and then returns the IUsbTargetPipeContinuousReaderCallbackReadComplete interface pointer.
  3. In the implementation of the IUsbTargetPipeContinuousReaderCallbackReadComplete::OnReaderCompletion method, access the data read that was read from the pipe. The pMemory parameter points to the memory allocated by the framework that contains the data. You can call IWDFMemory::GetDataBuffer to get the buffer that contains the data. The buffer includes the header however the length of data indicated by the NumBytesTransferred parameter of OnReaderCompletion does not include the header length. The header length is specified by the client driver while configuring the continuous reader in the driver's call to IWDFUsbTargetPipe2::ConfigureContinuousReader.
  4. Supply a pointer to the completion callback in the pOnCompletion parameter of the IWDFUsbTargetPipe2::ConfigureContinuousReader method.

Each time that data is available on the endpoint on the device, the target pipe object completes a read request. If the read request completed successfully, the framework notifies the client driver by calling IUsbTargetPipeContinuousReaderCallbackReadComplete::OnReaderCompletion. Otherwise, the framework calls a client driver-supplied failure callback when the target pipe object reports an error on the read request.

The following example code implements the IUsbTargetPipeContinuousReaderCallbackReadComplete interface on the device callback object.

The following example code shows the QueryInterface implementation of the device callback object.

The following example code shows how to get data from the buffer returned by IUsbTargetPipeContinuousReaderCallbackReadComplete::OnReaderCompletion. Each time the target pipe object completes a read request successfully, the framework calls OnReaderCompletion. The example gets the buffer that containsng data and prints the contents on the debugger output.

Download Fluke Usb Devices Driver Win 7

The client driver can get notifications from the framework when a failure occurs in the target pipe object while completing a read request. To get notifications, the client driver must implement a failure callback and supply a pointer to the callback while configuring the continuous reader. The following procedure describes how to implement the failure callback.

Provide a failure callback by implementing IUsbTargetPipeContinuousReaderCallbackReadersFailed

Download Fluke USB Devices Driver

  1. Implement the IUsbTargetPipeContinuousReaderCallbackReadersFailed interface on the device callback object.

  2. Make sure the QueryInterface implementation of the device callback object increments the reference count of the callback object and then returns the IUsbTargetPipeContinuousReaderCallbackReadersFailed interface pointer.

  3. In the implementation of the IUsbTargetPipeContinuousReaderCallbackReadersFailed::OnReaderFailure method, provide error handling of the failed read request.

    If the continuous reader fails to complete a read request and the client driver provides a failure callback, the framework invokes the IUsbTargetPipeContinuousReaderCallbackReadersFailed::OnReaderFailure method. The framework provides an HRESULT value in the hrStatus parameter that indicates the error code that occurred in the target pipe object. Based on that error code you might provide certain error handling. For example, if you want the framework to reset the pipe and then restart the continuous reader, make sure that the callback returns TRUE.

    Note Do not call IWDFIoTargetStateManagement::Start and IWDFIoTargetStateManagement::Stop within the failure callback.

  4. Supply a pointer to the failure callback in the pOnFailure parameter of the IWDFUsbTargetPipe2::ConfigureContinuousReader method.

Fluke Driver Download

The following example code implements the IUsbTargetPipeContinuousReaderCallbackReadersFailed interface on the device callback object.

The following example code shows the QueryInterface implementation of the device callback object.

The following example code shows an implementation of a failure callback. If a read request fails, the method prints the error code reported by the framework in the debugger and instructs the framework to reset the pipe and then restart the continuous reader.

If the client driver does not provide a failure callback and an error occurs, the framework resets the USB pipe and restarts the continuous reader.

Related topics

USB I/O Transfers
How to enumerate USB pipes
How to Select a Configuration for a USB Device
How to select an alternate setting in a USB interface