Communication Ports: BAS port (Port 1A): EIA-485 port for BACnet MS/TP communications, Modbus communications (future) or N2 communications (future). Baud rate is DIP switch selectable. LON-OC Port: For connecting a LON Option Card (future) Local Access Port: For system start-up and troubleshooting (115.2 kbps) Rnet Port: For connecting Carrier communicating space sensors. Interpersonal Communication came to being when men began to exchange ideas and thoughts to one another. Interpersonal Communication is a kind of communication in which people communicate their feeling, ideas, emotions and information face to face to each other. The Intelligent Platform Management Interface (IPMI) is a set of computer interface specifications for an autonomous computer subsystem that provides management and monitoring capabilities independently of the host system's CPU, firmware (BIOS or UEFI) and operating system.IPMI defines a set of interfaces used by system administrators for out-of-band management of computer systems. A Commercial Driver License (CDL) authorizes an individual to operate a commercial motor vehicle or combination of motor vehicles used to transport passengers or property. Individuals applying for a Commercial Driver License should recognize that this is a professional license with more testing requirements than other licenses. Use the TCP/IP functions located on the Functions»Data Communication»Protocols»TCP palette for TCP communication in LabVIEW. As with DAQ, instrument, and File I/O communication, the process involves opening the connection, reading and writing the information, and closing the connection.

These are general guidelines for connecting, downloading and uploading from an S7-300 or S7-400 PLC. The following procedures were created using Siemens SIMATIC STEP 7 version 5.4 software.

To start, open the SIMATIC Manager.

Now follow the links below.

The Programming Cables

There are three major types of programming cables:

Jobs

1. The CP5512 card in a PCMCIA slot.

2. The PC Adapter using a serial or USB connection

3. An Ethernet cable

The CP5512 card and the PC Adapter can communicate on either an MPI or PROFIBUS port. Note that PROFIBUS is labeled as DP on the Siemens connection ports. These cables can piggyback on existing connectors. Be aware that the PC Adapter draws its power to work from the connection port so check the power LED for proper operation. The CP5512 card draws its power from the computer.

For Ethernet (TCP/IP) use a standard Ethernet cable from the computer to a CPU with an Ethernet port, a CP 343/443 module or a network switch all ready attached to the PLC network.

Checking Communications

With the programming cable plugged in, you can check for proper operation by clicking on the Accessible Nodes icon.

Driver

If communications are successful, you'll see a window pop up similar to the one below. If so, then close the Accessible Nodes window and proceed to the download or upload section.

If communication fails then you will receive a message like below.

This indicates that the cable is not in the right computer port or the cable is not plugged in properly.

Setting the PG/PC Interface

In order to start communication to the PLC you will need to match the 'PG Interface' setting with the programming cable and protocol. To do this, select the menu Options > Set PG/PC Interface.

The following dialog box will open up displaying all the different interfaces (i.e. communication drivers).

Each cable has its own interface. For Ethernet select the TCP/IP interface for your computers network card. Be careful not to select your wireless Ethernet connection.

To get it working quickly it is best to select the interface with the Auto designation. This will discover working settings and use them automatically.

For the PC Adapter click on the Properties button and make sure the Station Parameters Address is a unique network address. It should not conflict with existing PLC and slave devices on the network. Also, check under the Local Connection tab and make sure connection selection matches the port the cable is connected into.

Once the proper interface is selected and the properties are set then click OK and use the Accessible Nodes window to check for successful communications. It should work. If not double-check the connection and cable. With the CP5512 and PC Adapter cables, you should use the MPI port, as this is the default connection for Siemens.

If this doesn't work then I don't know what to tell you.

First, in order to enable the download menu commands, you must select the Block folder in the project's station you wish to download.

There are three methods of downloading.

  1. Partial download of selected blocks
  2. Full download of all blocks and system data
  3. Complete deletion of online PLC blocks and then downloading of all blocks and system data

Partial Download

Partial downloads are used in existing projects where only one or more blocks will be downloaded. To perform this type of download select the block(s) you wish to download and then select the PLC > Download menu item or the download button .

I-view Communication Driver Jobs

Holding down the Ctrl key or the Shift key allows more then one block to be selected at a time. Be careful though as the order of download will occur in the order that the blocks were selected. This may mean that an error will occur if a block is called before it is downloaded.

The CPU will need to be in Stop mode before downloading the System Data Block (SDB) as this is equivalent to a hardware configuration download. This is usually not necessary in a PLC that has all ready had its hardware configured. If you do download the system data, the following messages will prompt you through the transitions.

If the CPU is in Run mode then you will be prompted to Stop the CPU. The software will do the Run to Stop transition when you click OK.

After downloading the SDB you will be prompted to Run the CPU again.

Clicking Yes will automatically put the CPU back into run mode.

Full Download

To download all the blocks at once make sure you are in the Block folder and select the Edit > Select All menu item. Click on the Download icon . You will be prompted to overwrite any existing blocks and if you want to load the system data (see above).

Clearing the CPU Memory and then Downloading

The partial and full download methods above will overwrite existing blocks but will not any blocks from memory. In order to completely delete the existing program in the CPU and download a new project select the Blocks folder and then use the PLC > Download User Program to Memory Card menu item.

The following dialog box will pop up prompting you about the deletion of all the blocks and project data in the PLC. Click Yes to perform the operation.

After this, follow the normal download procedure.

There are two methods for uploading. The first is when you have the original project and you want to preserve the symbols and comments. The second method, when you don't have the original project, will upload everything from the CPU but will have no associated documentation (i.e. symbols and comments).

Uploading to an Existing Project

With the existing project open, select the View > Online menu item.

This is the same as the Online button on the icon bar.

This will open up another window called the Online Partner. It shows the existing blocks inside the CPU. The Online version is indicated by the highlighted title bar.

I-view Communication Driver

There is a connection between these two versions so that uploading from the online partner makes sure to preserve all the symbols and comments. Be careful. After uploading, make sure to close the online partner and do all work from the offline version.

To upload individual blocks, select them in the Online view and choose the PLC > Upload to PG menu item. For a full upload, select the Block folder and do the same.

Upload without an Existing Project

Driver communication style

Follow these steps when you do not have the original project but wish to upload the program for backup purposes. With an existing project open or a new blank project select the PLC > Upload Station to PG… menu selection.

In the next screen, fill in the slot the CPU is in (this is always 2 for S7-300) and the node address of the communication port on the CPU. In the case below we are talking to a CPU over MPI with node address 10.

After clicking OK, the whole contents of the PLC including all blocks and hardware configuration will be uploaded into a new station in the project.

While this project contains no documentation, it can be used as a backup to download later if needed.

Configuring the RSLinx DF1 Driver

Driver Communication Style

In this section, we’ll set up the RSLinx DF1 Driver. Communications is very important in Industrial Automation. If you cannot communicate, you cannot go online to troubleshoot or change the program in your system. This document will guide you through Configuring the DF1 Driver in RSLinx. RSLinx is the communication server that interfaces between your processor and RSLogix/Studio 5000. We will use the same procedure to an SLC5/03 or higher, Micrologix, or PLC-5. The ControlLogix L6x or earlier has a serial port by you can communicate using the DF1 Driver.

What you will need:

I-view Communication Driver

To communicate with your ControlLogix system, you will need a 1756-CP3 cable (or other null modem cable). You will also need RSLogix/Studio 5000 installed on your computer with RSLinx, and an available RS232 port on your PC. New computers are not usually equipped with an RS232 port, so you can use a USB to Serial adapter.

If you are using a Micrologix 1000, please use a 1761-CBL-PM02 cable. If you are connecting to a PLC-5, realize that the PLC-5 has a 25pin RS232 port, so you may need a 9 to 25 pin adapter.

1) Open RSLinx Communication server

Access RSLinx at it’s default location, which is under Start | All Programs | Rockwell Software | RSLinx | RSLinx Classic. If your computer has a shortcut on the desktop to access RSLinx, you will see the following icon:

2) Go to the “Configure Drivers” screen

I-view Communication Driver Training

Next, we will click on Communications | Configure Drivers within RSLinx. A driver is just a set of instructions that tell your software how to interface with the hardware.

3) Choose “RS232 DF1 Devices”

The list of drivers can look very intimidating, but keep in mind that there are probably only a few drivers on the list that you may need to be concerned with for your location. Of course we need to choose the RS232 DF1 Devices driver.

Next, you will be prompted to enter a name for the driver. Here, we can just hit OK.

4) Configure the RSLinx DF1 Driver

RSLinx makes this step very easy. We do need to know which COM port your RS232 port is appearing at though. If you are unsure of this, go to your “Device Manager” in Windows. Then, press the + next to ports, then you will see the COM Ports that are available. In our case, the port is COM1. As long as you are connected to the processor, and the port is set at DF1 (which is default), you should have no problem using the Autoconfiguration feature. Finally, press the Autoconfig button, and you should get a message that the Autoconfiguration completed successfully. Finally, press OK, and close the “Configure Drivers” screen.

5) Verify Communication through the RSLinx DF1 Driver

Of course to make sure you are communicating, go to the RSWho Screen. The RSWHO screen will verify communication.

Next, select the DF1 Driver on the left side of your screen.

Consequently, you will see your processor appear on the right side of the screen.

For more information, visit the SLC-500 or ControlLogix Category Page.

I-view Communication Driver Job